ENERGETIKA. Proceedings of CIS higher education institutions and power engineering associations

Advanced search
Vol 64, No 5 (2021)
View or download the full issue PDF (Russian)
https://doi.org/10.21122/1029-7448-2021-64-5

ELECTRICAL POWER ENGINEERING

381-392 678
Abstract

The paper deals with the modeling of the processes of charge-discharge of battery assemblies taking into account their degradation. The results of simulating the cyclic operation of battery assemblies in the Electronics Workbench electronic laboratory are presented, possible schemes of inclusion are given, and options for re-switching batteries during operation are considered as well as connecting additional elements to extend the life of the connection. The simulation took into account the presence of one defective battery in the assembly. The operation of the assembly with a defective battery and a reference battery was compared. As a result of the analysis of parallel-serial and serial-parallel battery connections, the first one is considered preferable. For an assembly with a parallel-serial connection, the time parameters of operation remained almost unchanged, but the differences in the voltages of the defective and other batteries changed more than twice as compared with a serial-parallel connection. The changes in charge, voltage and current of assemblies with a degraded battery and a reference battery are analyzed. Timing diagrams are shown for batteries connected in parallel and in series with defective batteries. Power losses in a defective battery are reduced by choosing a parallel-series assembly, while switching a connection from a serial-parallel connection to a parallel-series one does not lead to compensation for the degradation of battery parameters. Changing the switching time intervals in a wide range does not contribute to increasing the capacity of a defective battery. Degradation of battery parameters leads to sharper surges in voltage, charge and current. The additional power recharge of the defective battery maintains the performance of the entire assembly. Recharge can be performed by connecting in parallel a defective additional battery or a capacitor, which is equivalent to replacing a degraded battery with a new one.

393-407 1481
Abstract

The paper deals with the problem of increasing the efficiency of the functioning of electric networks up to 1 kV, namely, the possibility of increasing the sensitivity of protections in networks up to 1 kV, which helps to reduce the protection response currents and, accordingly, reduce the cross-section of cable and wire products. The topicality of this problem is shown and the research tasks are defined. Much attention is paid to the concept of selectivity; attention is also paid to the concepts of full and partial selectivity. “Which protective devices can be considered selective?” is a question that is considered and worked out in sufficient depth in the paper. The negative phenomena that occur when ensuring the selectivity of protections in networks up to 1 kV are systematized and described in detail. Based on a comparative analysis of the parameters of circuit breakers with release tripping devices of various types, a solution to this problem is proposed by using circuit breakers with microprocessor and semiconductor release tripping devices. Additional advantages of microprocessor-based circuit breakers are considered and indicated, as well as their disadvantages are indicated, too. The main expected positive effects from the use of circuit breakers with microprocessor release tripping devices are listed, taking into account the fact that this type of circuit breakers is considered as a complex of devices replaced by it. The article can be recommended to employees of electric power specialties working with networks up to 1 kV.

408-420 827
Abstract

The paper deals with the problem of improving the reliability of DC-DC power supplies with pulse-width modulation. The topicality of the work is related to the importance of power supply issues in modern electronics, since the quality of operation of consumer electrical appliances, including critical ones, directly depends on the serviceability of sources. The object of the study is feedback circuits aimed at stabilization of the parameters of power supply of consumers. Failures of the mentioned feedback circuits most often occurs due to the electronic components degradation under harsh operating conditions as well as under severe mechanical overloads. Such failures are dangerous for uncontrolled increase of power supply output voltage and output current. To avoid this, a new method of reserving voltage feedback signals is presented in the paper which is implemented on the basis of flyback supply topology. Feedback signals are formed from the optocoupler located on the load side and from the auxiliary winding of the power transformer, together forming two independent output voltage control circuits. Only one circuit performs stabilization at any given moment of time. If one of these circuits fails, the second one can simply replace it in its operation. The proposed method does not require any digital signal processing algorithms or microprocessor control modules and can be implemented on the basis of cheap, widely available analog chips that perform pulse-width control of the output voltage. As a result, the problem of sudden feedback loop failure is solved and the reliability of electrical equipment is increased. The validity of the proposed method is confirmed by the results of computer simulation with the use of MatLab-Simulink environment. The obtained results can be used in design of fault-tolerant secondary power supplies that operate in harsh operating conditions.

421-434 930
Abstract

. Methods and mathematical models for studying the modes and characteristics of the three-phase squirrel-cage induction motor with the power supplied to the stator winding from the current source have been developed. The specific features of the algorithms for calculating transients, steady-state modes and static characteristics are discussed. The results of the calculation of the processes and characteristics of induction motors with the power supply from the current source and the voltage source are compared. Steady-state and dynamic modes cannot be studied with a sufficient adequacy based on the known equivalent circuits; this requires using dynamic parameters, which are the elements of the Jacobi matrix of the system of equations of the electromechanical equilibrium. In the mathematical model, the state equations of the stator and rotor circuits are written in the fixed two-phase coordinate system. The transients are described by the system of differential equations of electrical equilibrium of the transformed circuits of the motor and the equation of the rotor motion and the steady-state modes by the system of algebraic equation. The developed algorithms are based on the mathematical model of the motor in which the magnetic path saturation and skin effect in the squirrel-cage bars are taken into consideration. The magnetic path saturation is accounted for by using the real characteristics of magnetizing by the main magnetic flux and leakage fluxes of the stator and rotor windings. Based on them, the differential inductances are calculated, which are the elements of the Jacobi matrix of the system of equations describing the dynamic modes and static characteristic. In order to take into account the skin effect in the squirrel-cage rotor, each bar along with the squirrel-cage rings is divided height-wise into several elements. As a result, the mathematical model considers the equivalent circuits of the rotor with different parameters which are connected by mutual inductance. The non-linear system of algebraic equations of electrical equilibrium describing the steady-state modes is solved by the parameter continuation method. To calculate the static characteristics, the differential method combined with the Newton’s Iterative refinement is used.

435-445 575
Abstract

Basic EPS objects, which service life has exceeded normative value, increasingly affect – every year to a greater extent – the efficiency of overall performance. This manifests itself in increase of a number of automatic emergency shutdowns, an amount and complexities of accident-hazardous defects. After the expiration of the standard service life, there is a special need for a quantitative assessment of reliability and safety of an object. It is recommended to organize the operation, maintenance and repair of these objects according to their technical condition, and since it determines the reliability and safety of the object, these properties should be taken into account more fully. The relevant recommendations in electric power systems are implemented at a qualitative level, intuitively, according to the operating experience. There are neither quantitative evaluations nor methodology for their performance. Therefore, a method and algorithm of quantitative assessment of integral indicators of reliability and safety of operation of thermal power units of thermal power plants as concentrated objects of continuous operation were previously analyzed by the authors. The present paper examines distributed objects of continuous operation, viz. overhead power transmission lines with a voltage of 110 kV and higher, whose service life exceeds the standard value. Attention is paid to the issues of quantitative assessment of the degree of aging for a set of overhead power transmission lines, classification of these lines to identify the most significant classes and methodology for assessing the difference in the degree of aging when classifying them according to specified types of signs (for example, the difference in the degree of aging of overhead power transmission lines of grid enterprises of electric power systems). It is shown that it unacceptable to use the estimates of the relative number of overhead power transmission lines, the service life of which exceeds the calculated one, for comparison since it causes a great risk of an erroneous decision. The methodology and algorithm of methodological support of the management of electric power systems and grid enterprises in the organization of operation, maintenance and repair have been developed.

НEAT POWER ENGINEERING

426-458 559
Abstract

Abstaract. An analytical solution of a system of partial differential equations describing the unsteady isothermal flow of real gases in gas pipelines is considered. Such a problem arises when 

studying the regularity of alterations in the instantaneous values of pressure and gas flow in main gas pipelines, for example, during startups and shutdowns of large gas consumers. Meanwhile, transients are not necessarily of a pronounced oscillatory nature, despite the fact that they are described by periodic functions. In the course of the research, the task was set to obtain a mathematical model of the process taking into account the inertial term of the equation of motion, the neglect of which is possible only if the friction losses are exceeded by 3.5–4 times over the shock pressure. An important feature of the solution that have been found is its universality, which makes it possible to significantly reduce labor costs when using it to find partial solutions to practical problems that differ in boundary conditions. The boundary conditions of the first kind are given as an arbitrary function of both the gas flow rate and its pressure. The solution is based on the widely used method of separation of Fourier variables. In order to simplify the calculations, the original differential equation is transformed in such a way that the boundary conditions acquire the property of homogeneity. It has been determined that the requirements that the boundary conditions are equal to zero at the initial moment of time introduced into the solution make it possible to obtain a concise record of the obtained analytical model, but do not limit the area of the use of the model with a surge change in the gas flow rate or pressure. The obtained analytical model of unsteady gas flow makes it possible, without using the Duhamel integral, to find analytical solutions under more complex boundary conditions than the flow rate jump. At the same time, the solutions found completely coincide with the solutions based on the Duhamel integral, but in the course of the solution that we have found it is possible to avoid integration, which has a positive effect on the applicability of this approach in the practice of engineering calculations.

459-474 1562
Abstract

This paper considers the possibility of using vortex devices for interphase interaction while carrying out various physical and chemical processes in the chemical, food, gas production, construction and other industries. In the processes of mass transfer, one or several distributed components perform the transition from one phase to another through the active surface of their interface. To perform the implementation of these processes in absorbers, rectifiers, adsorbers, extractors effectively, the developed surface of the interacting phases acquire s a particular significance. Most of the chemical reactions in reaction devices and heterogeneous media occur when the initial distributed substances are supplied to the reaction zone and when the resulting products are removed from the chemical interaction zone through the phase interface. The processes under consideration are also used in solving environmental problems, viz. for sanitary cleaning of ventilation gases, wet cleaning of emissions. During evaporation, absorption, rectification, wet cleaning of gases and other processes, the problem of preventing the entrainment of liquid droplets with the gas flow is of great importance. One of the designs of a rotary multistage mass transfer apparatus is considered which makes it possible to achieve a finely dispersed liquid spray, uniform in height, with an ascending cross-flow of gas. The diagrams of installations for carrying out the experiment are given. On the basis of experimental studies, the dependence of the average diameter of dispersed liquid droplets on the geometric and hydrodynamic parameters has been obtained. The dispersed composition is described and dependences are given for determining the main characteristics used in physicochemical processes. The theoretical calculation of the movement of particles of the dispersed phase in the working volume of the apparatus at different flow rates of liquid and gas has been carried out. Theoretical and experimental methods were used to estimate the carryover of the liquid phase, an analysis of the process was carried out, and practical recommendations were given.