Technique of Performance Improvement of the Microprocessor-Based Protection Measuring Element
https://doi.org/10.21122/1029-7448-2019-62-5-403-412
Abstract
The technique is proposed to improve the performance of the measuring element of microprocessor-based protection and its implementation is considered at the software level. Two factors mainly influence on the performance of the measuring elements of microprocessorbased protection of electrical installations. The first one is associated with the appearance of aperiodic and harmonic components in the measured signals due to transients and nonlinearity of the electrical installation elements, and the second–with the inertia of information processing algorithms, in particular–with analog and digital filtering. This leads to the fact that the signal determining time at the output of the measuring element is delayed to unacceptable values that in some cases makes the high-speed protection of electrical equipment ineffective. To solve this problem, it is proposed to form the output signal of the measuring element in the form of special equivalent signals, which are a function of the pre-calculated correction factor and orthogonal components of the controlled signal. In the MatLab-Simulink dynamic modeling environment a mathematical model of the developed measuring element has been implemented, as well as a model of the elements of the power system. Checking the functioning of the model of the measuring element was carried out with the use of 2 types of test effects, viz. a sinusoidal signal with a frequency of 50 Hz (idealized effect), as well as a signal close to the real secondary current of the current transformer in case of short circuit. Computational experiments carried out in relation to the current measuring element using harmonic and close-to-real test effects made it possible to reveal a significant (up to 2 times) increase in the performance of the proposed measuring element as compared to existing ones based on the implementation of the discrete Fourier transform.
About the Authors
F. A. RomaniukBelarus
Address for correspondence: Romaniuk Fiodar A. – Belаrusian National Technical University, 65/2 Nezavisimosty Ave., 220013, Minsk, Republic of Belarus. Tel.: +375 17 331-00-51 faromanuk@bntu.by
V. Yu. Rumiantsev
Belarus
Minsk
I. A. Novash
Belarus
Minsk
Yu. V. Rumiantsev
Belarus
Minsk
References
1. Shneerson E. M. (2007) Digital Relay Protection. ?oscow, Energoatomizdat Publ. 594 (in Russian).
2. Romaniuk F. A., Rumjansev V. Y., Romaniuk K. F. (2012) Principles of Fulfillment of Flexible Formers of Orthogonal Input Value Components in Micro-Processing Protection of Power Plants. Energetika. Izvestiya Vysshikh Uchebnykh Zavedenii i Energeticheskikh Obedinenii SNG = Energetika. Proceedings of CIS Higher Education Institutions and Power Engineering Associations, (6), 5–10 (in Russian).
3. Rumiantsev Y. V., Romaniuk F. A., Rumiantsev V. Y., Novash I. V. (2018) Digital Current Measurement Element for Operation During Current Transformer Severe Saturation. Energetika. Izvestiya Vysshikh Uchebnykh Zavedenii i Energeticheskikh Obedinenii SNG = Energetika. Proceedings of CIS Higher Education Institutions and Power Engineering Associations, 61 (6), 483-493 (in Russian). https://doi.org/10.21122/1029-7448-2018-61-6-483-493
4. Romaniuk F., Rumiantsev V., Dziaruhina A., Kachenya V. (2019) Increase of Operation speed of Digital Measuring Elements of Microprocessor Protection of Electrical installations. New Electrical and Electronic Technologies and their Industrial Implementations: 11th International Conference, Zakopane, Poland, June 25–28. Zakopane, 56.
5. Rumiantsev Yu. V., Romaniuk F. A., Rumiantsev V. Yu., Novash I. V. (2016) Digital Filters Implementation in Microprocessor-Based Relay Protection. Energetika. Izvestiya Vysshikh Uchebnykh Zavedenii i Energeticheskikh Obedinenii SNG = Energetika. Proceedings of CIS Higher Education Institutions and Power Engineering Associations, 59 (5), 397–417 (in Russian). https://doi.org/10.21122/1029-7448-2016-59-5-397-417
6. Romaniuk F., Rumiantsev V., Novash I., Rumiantsev Y., Boiko O. (2016) Comparative Assessment of Digital Filters for Microprocessor-Based Relay Protection. Przegl?d Electrotechniczny (Electrical Review), 1 (7), 130-133. https://doi.org/10.15199/48.2016.07.28
7. Romaniuk F. A., Loman ?. S., Kachenya V. S. (2019) Methods of Forming Orthogonal Components of Input Signals for Relay Protection. Energetika. Izvestiya Vysshikh Uchebnykh Zavedenii i Energeticheskikh Obedinenii SNG = Energetika. Proceedings of CIS Higher Education Institutions and Power Engineering Associations, 62 (1), 5–14 (in Russian). https://doi.org/10.21122/1029-7448-2019-62-1-5-14
8. SimPowerSystems. User’s Guide. The MathWorks, Inc. 2012. 411.
9. Novash I. V., Rumiantsev Yu. V. (2015) A Simplified Model of Three-Phase Bank of Current Transformers in the Dynamic Simulation System. Energetika. Izvestiya Vysshikh Uchebnykh Zavedenii i Energeticheskikh Obedinenii SNG = Energetika. Proceedings of CIS Higher Education Institutions and Power Engineering Associations, (5), 23–38 (in Russian).
10. Romanyuk F., Novash I., Rumiantsev Y., W?gierek P. (2015) Wye-Connected Current Transformers Simplified Model Validation in MATLAB–Simulink. Przegl?d Electrotechniczny (Electrical Review), 1 (11), 294–297. https://doi.org/10.15199/48.2015.11.67
Review
For citations:
Romaniuk F.A., Rumiantsev V.Yu., Novash I.A., Rumiantsev Yu.V. Technique of Performance Improvement of the Microprocessor-Based Protection Measuring Element. ENERGETIKA. Proceedings of CIS higher education institutions and power engineering associations. 2019;62(5):403-412. (In Russ.) https://doi.org/10.21122/1029-7448-2019-62-5-403-412