Higher Efficiency of Turbine Qil Purification
https://doi.org/10.21122/1029-7448-2004-0-2-61-67
Abstract
Analysis of turbine oil purification has made it possible to ascertain the reason of failures in the system of T-200-130 LMZ turbine-driven set at South Urals Hydroelectric Power Station. This reason is non-effective operation of a coarse filter and high wear of a bearing No.4. The filter has been modernized and the required normative oil purity in the system of bearing lubrication and turbine-driven set regulation has been obtained.
It has been shown that sieve fabric of polyamide monofilaments ensures effective filtration of contaminated oil in the system of bearing lubrication and steam turbines.
Particle-size analysis of turbine oil impurities in various points of oil supply system can be used for technical diagnostics of turbine-driven set bearings.
About the Authors
E. V. ToropovRussian Federation
I. F. Pshenisnov
Russian Federation
A. I. Pshenisnov
Russian Federation
Ya. I. Pshenisnov
Russian Federation
References
1. Надежность теплоэнергетического оборудования ТЭС и АЭС / Г. П. Гладышев, Р. 3. Аминов, В. 3. Гуревич и др.; Под ред. А. И. Андрющенко. - М: Высш. шк., 1991. -303 с.
2. Торопов Е. В., Пшениснов А. И. Очистка турбинного масла в системе маслоснабжения и регулирования Т-180/210 ЛМЗ до нормативной чистоты // Энергетика... (Изв. высш. учеб, заведений и энерг. объединений СНГ). - 1998. - № 4. - С. 5А-61.
3. Рыбаков К. В., Коваленко В. П. Фильтрование авиационных масел и специальных жидкостей. - М.: Транспорт, 1977. - 188 с.
4. Коновалов В. М., Скрицкий В. Я., Рокшевский В. А. Очистка рабочих жидкостей в гидроприводах станков. - М.: Машиностроение, 1976. - 261 с
Review
For citations:
Toropov E.V., Pshenisnov I.F., Pshenisnov A.I., Pshenisnov Ya.I. Higher Efficiency of Turbine Qil Purification. ENERGETIKA. Proceedings of CIS higher education institutions and power engineering associations. 2004;(2):61-67. (In Russ.) https://doi.org/10.21122/1029-7448-2004-0-2-61-67