Experience of Steam and Gas Unit Running-In at the Orsha Thermal Power Station
https://doi.org/10.21122/1029-7448-2004-0-1-34-39
Abstract
Some data on technical characteristics and running-in of the steam and gas unit at the Orsha Thermal Power Station are given in the paper. The paper contains results of the regime optimization and research in respect of higher operational efficiency of steam and gas unit under partial thermal loadings.
About the Authors
A. D. KachanBelarus
Professor, PhD in Engineering
S. A. Kachan
Belarus
Associate Professor, PhD in Engineering
G. N. Korolev
Belarus
Engineer
O. S. Makaev
Belarus
Engineer
K. I. Putilo
Belarus
Engineer
References
1. .Ольховский Г. Г. Энергетические газотурбинные установки. - М.: Энергоатом- издат, 1985. - 304 с.
2. Качан А. Д., Качан С. А. Оптимизация режимов работы утилизационных ПГУ с противодавленческими паровыми турбинами // Энергетика... (Изв. высш. учеб, заведений и энерг. объединений СНГ). - 2000. - № 4. - С. 49-55.
Review
For citations:
Kachan A.D., Kachan S.A., Korolev G.N., Makaev O.S., Putilo K.I. Experience of Steam and Gas Unit Running-In at the Orsha Thermal Power Station. ENERGETIKA. Proceedings of CIS higher education institutions and power engineering associations. 2004;(1):34-39. (In Russ.) https://doi.org/10.21122/1029-7448-2004-0-1-34-39