<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">energy</journal-id><journal-title-group><journal-title xml:lang="ru">Энергетика. Известия высших учебных заведений и энергетических объединений СНГ</journal-title><trans-title-group xml:lang="en"><trans-title>ENERGETIKA. Proceedings of CIS higher education institutions and power engineering associations</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1029-7448</issn><issn pub-type="epub">2414-0341</issn><publisher><publisher-name>BNTU</publisher-name></publisher></journal-meta><article-meta><article-id custom-type="elpub" pub-id-type="custom">energy-907</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ЭЛЕКТРОЭНЕРГЕТИКА</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>ELECTRICAL POWER ENGINEERING</subject></subj-group></article-categories><title-group><article-title>ОПРЕДЕЛЕНИЕ ТОКОВ УТЕЧКИ ЧЕРЕЗ ИЗОЛЯЦИОННОЕ ПОКРЫТИЕ ПРОВОДОВ ВЛП 10 кВ ПРИ КАСАНИИ ДЕРЕВЬЕВ И ДРУГИХ ЗАЗЕМЛЕННЫХ ПРЕДМЕТОВ ПОД ДОЖДЕМ</article-title><trans-title-group xml:lang="en"><trans-title>DETERMINATION OF LEAKAGE CURRENT THROUGH INSULATED COATING OF 10 KV OVERHEAD DISTRIBUTION LINE WIRES WHILE CONTACTING TREES AND OTHER EARTHED OBJECTS IN RAINY WEATHER</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Степанчук</surname><given-names>К. Ф.</given-names></name><name name-style="western" xml:lang="en"><surname>Stepanchuk</surname><given-names>K. F.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Доктор технических наук, профессор</p></bio><bio xml:lang="en"><p>Professor, PhD in Engineering</p></bio><email xlink:type="simple">energy@bntu.by</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Климович</surname><given-names>Г. С.</given-names></name><name name-style="western" xml:lang="en"><surname>Klimovich</surname><given-names>G. S.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Кандидат технических наук, доцент</p></bio><bio xml:lang="en"><p>Associate Professor, PhD in Engineering</p></bio><email xlink:type="simple">energy@bntu.by</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Красько</surname><given-names>А. С.</given-names></name><name name-style="western" xml:lang="en"><surname>Krasko</surname><given-names>A. S.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Кандидат технических наук, доцент</p></bio><bio xml:lang="en"><p>Associate Professor, PhD in Engineering</p></bio><email xlink:type="simple">energy@bntu.by</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Ржевская</surname><given-names>С. П.</given-names></name><name name-style="western" xml:lang="en"><surname>Rzhevskaya</surname><given-names>S. P.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Кандидат технических наук, доцент</p></bio><bio xml:lang="en"><p>Associate Professor, PhD in Engineering</p></bio><email xlink:type="simple">energy@bntu.by</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Ломан</surname><given-names>М. С.</given-names></name><name name-style="western" xml:lang="en"><surname>Loman</surname><given-names>M. S.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Инженер</p></bio><bio xml:lang="en"><p>Engineer</p></bio><email xlink:type="simple">energy@bntu.by</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Белорусский национальный технический университет</institution><country>Беларусь</country></aff><aff xml:lang="en"><institution>Belarusian National Technical University</institution><country>Belarus</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2005</year></pub-date><pub-date pub-type="epub"><day>26</day><month>02</month><year>2005</year></pub-date><volume>0</volume><issue>1</issue><fpage>24</fpage><lpage>27</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Степанчук К.Ф., Климович Г.С., Красько А.С., Ржевская С.П., Ломан М.С., 2005</copyright-statement><copyright-year>2005</copyright-year><copyright-holder xml:lang="ru">Степанчук К.Ф., Климович Г.С., Красько А.С., Ржевская С.П., Ломан М.С.</copyright-holder><copyright-holder xml:lang="en">Stepanchuk K.F., Klimovich G.S., Krasko A.S., Rzhevskaya S.P., Loman M.S.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://energy.bntu.by/jour/article/view/907">https://energy.bntu.by/jour/article/view/907</self-uri><abstract><p>Исследования, проведенные на макете ВЛП при схлестывании проводов и попадании на них упавших деревьев и других заземленных предметов, показали, что в таком режиме ВЛП может работать длительное время. Однако за счет токов утечки опасные высокие потенциалы могут появиться на этих предметах и вокруг них. Приводятся результаты расчетов и экспериментальных исследований, которые показывают, что под дождем ток утечки на заземленный предмет и сопротивление изоляции зависят от ширины увлажненной зоны и практически не зависят от размеров и формы предмета. Для реальных пролетов ВЛП ток утечки не превышает 3 м × А при рабочем напряжении и 15 м × А – при возможных внутренних перенапряжениях, а полное сопротивление изоляции – не менее 3…4 м × Ом.</p></abstract><trans-abstract xml:lang="en"><p>Investigations that were conducted with the help of overhead distribution line model reflected such situations as wire swinging cross, their contact with fallen trees and other earthed objects have shown that the overhead lines may operate rather long under such conditions. However leakage current may lead to dangerous high potentials on these objects and around them.</p><p>The results of calculations and experimental research have revealed that in the rain leakage current on an earthed object and insulation resistance depends on the width of moistened zone and practically does not depend on an object size and shape. Leakage current does not exceed 3 mA at an operating voltage and 15mA at possible internal overvoltage and full insulation resistance is not less than  3…4 MW for actual overhead distribution line spans.</p></trans-abstract></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Степанчук К. Ф., Климович Г. С., Красько А. С. Срок службы изоляции покрытых проводов ВЛП 10 кВ при касании веток деревьев и других заземленных предметов // Энергетика… (Изв. высш. учеб. заведений и энерг. объединений СНГ). – 2002. – № 5 – С. 28–34.</mixed-citation><mixed-citation xml:lang="en">Степанчук К. Ф., Климович Г. С., Красько А. С. Срок службы изоляции покрытых проводов ВЛП 10 кВ при касании веток деревьев и других заземленных предметов // Энергетика… (Изв. высш. учеб. заведений и энерг. объединений СНГ). – 2002. – № 5 – С. 28–34.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Степанчук К. Ф., Климович Г. С., Красько А. С. Срок службы изоляции покрытых проводов ВЛП 10 кВ при схлестывании // Энергетика… (Изв. высш. учеб. заведений и энерг. объединений СНГ). – 2002. – № 3. – С. 22–26.</mixed-citation><mixed-citation xml:lang="en">Степанчук К. Ф., Климович Г. С., Красько А. С. Срок службы изоляции покрытых проводов ВЛП 10 кВ при схлестывании // Энергетика… (Изв. высш. учеб. заведений и энерг. объединений СНГ). – 2002. – № 3. – С. 22–26.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Степанчук К. Ф., Климович Г. С., Красько А. С. Определение токов утечки через сухое изоляционное покрытие проводов ВЛП 10 кВ при касании деревьев и других заземленных предметов // Энергетика… (Изв. высш. учеб. заведений и энерг. объединений СНГ). – 2004. – № 2. – С. 11–16.</mixed-citation><mixed-citation xml:lang="en">Степанчук К. Ф., Климович Г. С., Красько А. С. Определение токов утечки через сухое изоляционное покрытие проводов ВЛП 10 кВ при касании деревьев и других заземленных предметов // Энергетика… (Изв. высш. учеб. заведений и энерг. объединений СНГ). – 2004. – № 2. – С. 11–16.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
