<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">energy</journal-id><journal-title-group><journal-title xml:lang="ru">Энергетика. Известия высших учебных заведений и энергетических объединений СНГ</journal-title><trans-title-group xml:lang="en"><trans-title>ENERGETIKA. Proceedings of CIS higher education institutions and power engineering associations</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1029-7448</issn><issn pub-type="epub">2414-0341</issn><publisher><publisher-name>BNTU</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.21122/1029-7448-2018-61-1-5-14</article-id><article-id custom-type="elpub" pub-id-type="custom">energy-1140</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ЭЛЕКТРОЭНЕРГЕТИКА</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>ELECTRICAL POWER ENGINEERING</subject></subj-group></article-categories><title-group><article-title>ПОВЫШЕНИЕ ДОСТОВЕРНОСТИ ОПРЕДЕЛЕНИЯ ЗОНЫ КОРОТКОГО ЗАМЫКАНИЯ НА ЛИНИЯХ 6–35 кВ</article-title><trans-title-group xml:lang="en"><trans-title>THE RELIABILITY OF DETERMINING THE SHORT CIRCUIT ZONE OF THE LINES OF 6–35 kV</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Романюк</surname><given-names>Ф. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Romaniuk</surname><given-names>F. А.</given-names></name></name-alternatives><bio xml:lang="ru"/><bio xml:lang="en"/><email xlink:type="simple">faromanuk@bntu.by</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Булойчик</surname><given-names>Е. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Buloichyk</surname><given-names>E. V.</given-names></name></name-alternatives><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Гурьянчик</surname><given-names>О. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Huryanchyk</surname><given-names>O. A.</given-names></name></name-alternatives><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Каченя</surname><given-names>В. С.</given-names></name><name name-style="western" xml:lang="en"><surname>Kachenya</surname><given-names>V. S.</given-names></name></name-alternatives><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Белорусский национальный технический университет</institution><country>Беларусь</country></aff><aff xml:lang="en"><institution>Belarusian National Technical University</institution><country>Belarus</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2018</year></pub-date><pub-date pub-type="epub"><day>23</day><month>01</month><year>2018</year></pub-date><volume>61</volume><issue>1</issue><fpage>5</fpage><lpage>14</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Романюк Ф.А., Булойчик Е.В., Гурьянчик О.А., Каченя В.С., 2018</copyright-statement><copyright-year>2018</copyright-year><copyright-holder xml:lang="ru">Романюк Ф.А., Булойчик Е.В., Гурьянчик О.А., Каченя В.С.</copyright-holder><copyright-holder xml:lang="en">Romaniuk F.А., Buloichyk E.V., Huryanchyk O.A., Kachenya V.S.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://energy.bntu.by/jour/article/view/1140">https://energy.bntu.by/jour/article/view/1140</self-uri><abstract><p>В работе представлен способ повышения достоверности определения зоны короткого замыкания в токовых ступенчатых защитах линий 6–35 кВ с односторонним питанием с целью улучшения показателей их технического совершенства. Учитывая относительную простоту токовой защиты, наиболее целесообразным для реализации в алгоритме ее функционирования из существующих методов определения места повреждения представляется односторонний дистанционный метод по параметрам аварийного режима с учетом вида повреждения. Отмечены основные факторы, влияющие на достоверность определения зоны короткого замыкания на основе дистанционного метода. Методом вычислительного эксперимента исследовано влияние нагрузочных токов и переходных сопротивлений различного уровня на величину и характер изменения погрешностей определения расчетной удаленности места повреждения от места установки защиты при учете погрешностей измерительных трансформаторов. Показано, что во многих случаях дуговых коротких замыканий на нагруженной линии для определения зоны короткого замыкания с удовлетворительными погрешностями необходима коррекция расчетного расстояния до места повреждения, вычисленного по параметрам поврежденной петли (петель). По результатам вычислительного эксперимента получены корректирующие выражения на основе двух относительных несимметрий токов, определяемых по действующим значениям разностей фазных токов линии для выявления вида короткого замыкания. Выполнена оценка работоспособности предложенного способа. Показано, что применение этого способа коррекции позволяет повысить достоверность определения зоны повреждения. Исследованы динамические свойства предложенного метода для различных режимов работы линии. Установлено, что в наихудшем случае обеспечивается определение зоны повреждения за время, не превышающее 26 мс.</p></abstract><trans-abstract xml:lang="en"><p>A method of increasing the reliability of determining the zone of short-circuit at the current step protection of the lines of 6–35 kV with unilateral power, aimed at improvement of their technical perfection, is presented in the paper. Having taken the relative simpleness of the current protection into account the authors consider the unilateral remote method of accounting the parameters of the emergency mode and the type of fault to be the most suitable for the implementation of the algorithm of its functioning as compared with the existing methods of fault location. The major factors affecting the accuracy of determining the short circuit zone based on the remote method are noted. With the use of the method of computational experiment the influence of the load currents and contact resistances of various levels on the magnitude and character of changes of errors of determination of the calculated distance of the point of fault from the protection installation location taking into account the errors of measuring transformers. It is demonstrated that in many cases of arc short circuit in a loaded line in order to define the zone of short-circuit with fair accuracy correction of the estimated distance to the fault as calculated by the parameters of the damaged loop (loops) is required. According to the results of numerical experiments corrective expressions on the basis of two relative asymmetry currents determined by the current values of the differences of the phase currents of the line for detecting a type of a short circuit have been obtained. The assessment of the efficiency of the proposed method has been performed. It is shown that the application of the proposed correction method makes it possible to increase the accuracy of fault zone detection. The dynamic properties of the proposed method applied to different modes of the line functioning have been studied. It is determined that in the worst case the definition of the fault zone for a maximum duration of 26 μsec is provided.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>линия электропередачи</kwd><kwd>токовая защита</kwd><kwd>техническое совершенство</kwd><kwd>относительная несимметрия</kwd><kwd>зона короткого замыкания</kwd><kwd>переходное сопротивление</kwd><kwd>быстродействие</kwd></kwd-group><kwd-group xml:lang="en"><kwd>power line</kwd><kwd>current protection</kwd><kwd>technical excellence</kwd><kwd>relative asymmetry</kwd><kwd>short-circuit area</kwd><kwd>contact resistance</kwd><kwd>operation speed</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Федосеев, А. М. Релейная защита электроэнергетических систем / А. М. Федосеев, М. А. Федосеев. 2-е изд., перераб. и доп. М.: Энергоатомиздат, 1992. 528 с.</mixed-citation><mixed-citation xml:lang="en">Fedoseev A. M., Fedoseev M. A. (1992) Relay Protection of Electric Power Systems. 2nd ?d. Moscow, Energoatomizdat Publ. 528 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Басс, Э. И. Релейная защита электроэнергетических систем / Э. И. Басс, В. Г. Дорогунцев; под ред. А. Ф. Дьякова. М.: Изд-во МЭИ, 2002. 296 с.</mixed-citation><mixed-citation xml:lang="en">Bass E. I., Doroguntsev V. G., D'yakov A. F. (ed.) (2002) Relay Protection of Electric Power Systems. Moscow, MHEI Publ. 296 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Романюк, Ф. А. Определение места короткого замыкания на линиях радиальных сетей с односторонним питанием / Ф. А Романюк, А. А. Тишечкин, Е. В. Булойчик // Наука и техника. 2012. № 4. С. 69–73.</mixed-citation><mixed-citation xml:lang="en">Romaniuk F., Tishechkin A., Buloychik E. (2012) Detection of Short Circuit Location in Radial Network Lines with One-Side Supply. Nauka i Tekhnika = Science &amp; Technique, (4), 69–73 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Романюк, Ф. А. Определение места короткого замыкания на линиях распределительных сетей в объеме функций микропроцессорных токовых защит / Ф. А. Романюк, А. А. Тишечкин, О. А. Гурьянчик // Энергетика. Изв. высш. учеб. заведений и энерг. объединений СНГ. 2010. № 6. С. 5–13.</mixed-citation><mixed-citation xml:lang="en">Romaniuk F. A., Tishechkin A. A., Gurjanchik O. A. (2010) Detection of Short-Circuit Location in Distribution Mains Line within Functions of Micro-Processor Current Protection. Energetika. Izvestiya Vysshikh Uchebnykh Zavedenii i Energeticheskikh Ob’edinenii SNG = Energetika. Proceedings of CIS Higher Education Institutions and Power Engineering Associations, (6), 5–13 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Романюк, Ф. А. Определение места повреждения на линиях напряжением 6–35 кВ с односторонним питанием / Ф. А. Романюк, М. А. Шевалдин // Энергетика. Изв. высш. учеб. заведений и энерг. объединений СНГ. 2014. № 5. С. 5–14.</mixed-citation><mixed-citation xml:lang="en">Romaniuk F. A., Shevaldin M. A. (2014) Detection of Fault Location on the Power Lines 6–35 kV with Unilateral Feed. Energetika. Izvestiya Vysshikh Uchebnykh Zavedenii i Energeticheskikh Ob’edinenii SNG = Energetika. Proceedings of CIS Higher Education Institutions and Power Engineering Associations, (5), 5–14 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Шнеерсон, Э. М. Цифровая релейная защита / Э. М. Шнеерсон. М.: Энергоатомиздат, 2007. 549 с.</mixed-citation><mixed-citation xml:lang="en">Shneerson E. M. (2007) Digital Relay Protection. Moscow, Energoatomizdat Publ. 549 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Шнеерсон, Э. М. Дистанционные защиты / Э. М. Шнеерсон. М.: Энергоатомиздат, 1986. 448 с.</mixed-citation><mixed-citation xml:lang="en">Shneerson E. M. (1986) Distance Protection. Moscow, Energoatomizdat Publ. 448 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Аржанников, Е. А. Методы и приборы определения мест повреждения на линиях электропередачи / Е. А. Аржанников, А. М. Чухин. М.: НТФ «Энергопрогресс», 1998. 64 с. (Библиотечка электротехника, приложение к журналу «Энергетик». Вып. 3).</mixed-citation><mixed-citation xml:lang="en">Arzhannikov E. A., Chukhin A. M. (1998) Methods and Devices for the Localization of Faults of Power Lines. Electrical Engineer Small Library, Supplement to the “Energetik” Journal. Moscow, Energoprogress Publ. 64 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Определение вида повреждения в токовых защитах линий электропередачи 6–35 кВ / Ф. А. Романюк [и др.] // Энергетика. Изв. высш. учеб. заведений и энерг. объединений СНГ. 2017. Т. 60, № 6. С. 497–504. DOI: 10.21122/1029-7448-2017-60-6-497-504.</mixed-citation><mixed-citation xml:lang="en">Romaniuk F. A., Buloichik E. V., Huryanchyk O. A., Shevaldin M. A. (2017) Determining a Type of a Damage in the Current Protection of Power Lines of 6–35 kV. Energetika. Izvestiya Vysshikh Uchebnykh Zavedenii i Energeticheskikh Ob’edinenii SNG = Energetika. Proceedings of CIS Higher Education Institutions and Power Engineering Associations, 60 (6), 497–504 (in Russian). DOI: 10.21122/1029-7448-2017-60-6-497-504.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Новаш, И. В. Математическое моделирование коммутационных режимов в электроустановках с трансформаторами / И. В. Новаш, Ф. А. Романюк. Минск: БНТУ, 2013. 225 с.</mixed-citation><mixed-citation xml:lang="en">Novash V. I., Romaniuk F. A. (2013) Mathematical Modeling of Switching Modes in Electrical Systems with Transformers. Minsk, Belarusian National Technical University. 225 (in Russian). 11. Romaniuk F. A., Novash V. I. (1998) Information Support of Computing Experiment in Relay Protection and Automation of Power Systems. Minsk, VUZ-YuNITI Publ. 174 (in Russian)</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Романюк, Ф. А. Информационное обеспечение вычислительного эксперимента в релейной защите и автоматике энергосистем / Ф. А. Романюк, В. И. Новаш. Минск: ВУЗ-ЮНИТИ, 1998. 174 с.</mixed-citation><mixed-citation xml:lang="en">Романюк, Ф. А. Информационное обеспечение вычислительного эксперимента в релейной защите и автоматике энергосистем / Ф. А. Романюк, В. И. Новаш. Минск: ВУЗ-ЮНИТИ, 1998. 174 с.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
