<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">energy</journal-id><journal-title-group><journal-title xml:lang="ru">Энергетика. Известия высших учебных заведений и энергетических объединений СНГ</journal-title><trans-title-group xml:lang="en"><trans-title>ENERGETIKA. Proceedings of CIS higher education institutions and power engineering associations</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1029-7448</issn><issn pub-type="epub">2414-0341</issn><publisher><publisher-name>BNTU</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.21122/1029-7448-2017-60-5-484-492</article-id><article-id custom-type="elpub" pub-id-type="custom">energy-1090</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ТЕПЛОЭНЕРГЕТИКА</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>НEAT POWER ENGINEERING</subject></subj-group></article-categories><title-group><article-title>О НОВОЙ ТЕХНОЛОГИИ ПОДГОТОВКИ ГОРЯЧЕЙ ПИТЬЕВОЙ ВОДЫ</article-title><trans-title-group xml:lang="en"><trans-title>ON A NEW TECHNOLOGY OF PREPARATION OF HOT DRINKING WATER</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Джалилов</surname><given-names>М. Ф.</given-names></name><name name-style="western" xml:lang="en"><surname>Jalilov</surname><given-names>M. F.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Адрес для переписки:  Джалилов Мардан Фарадж оглы  – Азербайджанский архитектурно-строительный университет, ул. А. Сультановой, 5, AZ1073, г. Баку, Азербайджанская Республика. Тел.: +99 412 454-47-25   jalilovm@rambler.ru</p></bio><bio xml:lang="en"><p>Address for correspondence:  Jalilov Mardan F. – Azerbaijan University of Architecture and Construction, 5 A. Sultanovoy str., AZ1073, Baku, the Azerbaijani Republic Tel.: +99 412 454-47-25   jalilovm@rambler.ru</p></bio><email xlink:type="simple">jalilovm@rambler.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Азимова</surname><given-names>М. М.</given-names></name><name name-style="western" xml:lang="en"><surname>Azimova</surname><given-names>M. M.</given-names></name></name-alternatives><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Джалилова</surname><given-names>А. М.</given-names></name><name name-style="western" xml:lang="en"><surname>Jalilova</surname><given-names>A. M.</given-names></name></name-alternatives><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Азербайджанский архитектурно-строительный университет</institution><country>Азербайджан</country></aff><aff xml:lang="en"><institution>Azerbaijan University of Architecture and Construction</institution><country>Azerbaijan</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2017</year></pub-date><pub-date pub-type="epub"><day>28</day><month>09</month><year>2017</year></pub-date><volume>60</volume><issue>5</issue><fpage>484</fpage><lpage>492</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Джалилов М.Ф., Азимова М.М., Джалилова А.М., 2017</copyright-statement><copyright-year>2017</copyright-year><copyright-holder xml:lang="ru">Джалилов М.Ф., Азимова М.М., Джалилова А.М.</copyright-holder><copyright-holder xml:lang="en">Jalilov M.F., Azimova M.M., Jalilova A.M.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://energy.bntu.by/jour/article/view/1090">https://energy.bntu.by/jour/article/view/1090</self-uri><abstract><p>В статье приводятся сведения о новой технологии Cl-анионирования при подготовке горячей питьевой воды. Указанная технология в отличие от умягчения воды, где все соли жесткости замещаются в катионите катионами натрия, позволяет заменить накипеобразующие HCO-/3- и SO(2-)/4 -анионы в сильноосновном анионите Cl⁻-ионами. В результате предотвращается образование накипи на поверхностях нагрева подогревателей горячего водоснабжения. Таким образом, ценные для человеческого организма катионы жесткости остаются в составе воды, и ее качество удовлетворяет качеству питьевой воды. Учитывая важную роль кальция и магния для человеческого организма, в Германии и Турции ограничивается минимальное значение катионов жесткости в питьевой воде соответственно до 2,85 и 7,50 мг-экв/л. По данным Всемирной организации здравоохранения, в составе питьевой воды концентрация катионов магния и кальция рекомендуется соответственно в пределах 10–(20–30) и 20–50 мг/л; минимальное значение общей жесткости 2–4 мг-экв/л. Согласно разработанной технологии питьевая вода последовательно в направлении сверху вниз пропускается через механический и хлор-анионитный фильтры. В последнем основная часть HCO-/3- и SO(2-)/4-ионов воды обменивается на Cl-анионы анионита. Далее вода собирается в бак, откуда насосом через аппарат ультрафиолетовой дезинфекции подается в подогреватель горячего водоснабжения. После истощения анионита SO(2-)/4- и HCO-/3-анионами осуществляется его регенерация раствором (8–12)%-й NaCl. Излагаются результаты исследований анионитами Purolite A200EMBCl и АВ-17-8. Отмечается, что при удельном расходе соли на регенерацию около 45–55 кг/м³ рабочая обменная емкость A200EMBCl получается в пределах 300–370 г-экв/м³. При анионировании воды остаточная концентрация HCO-/3-ионов изменялась в пределах от 0,5 до 3,2 мг-экв/л. Средняя концентрация этих анионов при исходном их значении, равном 4,4 мг-экв/л, получилась в пределах от 1,8 до 2,2 мг-экв/л.</p></abstract><trans-abstract xml:lang="en"><p>The present article contains information concerning the new Cl-anionization technology in the preparation of hot drinking water. In contrast with water softening, that replaces all the hardness salts by sodium cations in the cation exchanger, this new technology makes it possible to replace incrustating HCO3̄ and SO42--anions in a strong-base anion exchanger by Cl⁻-ions. As a result, the incrustation on the surfaces of heating hot water heaters is prevented. Thus, cations of hardness that are valuable for the human body remain in the water, the quality of the latter conforming to drinking water quality. Considering the important role of calcium and magnesium in the human body, in Germany and Turkey the minimum value of hardness cations in drinking water is limited to 2.85 and 7.50 mg-Eqv/l, respectively. According to the World Health Organization, in the composition of drinking water, the concentration of cations of magnesium and calcium is recommended, respectively, within 10–(20–30), and 20–50 mg/l; the minimum value of total hardness is 2–4 mg-Eqv/l. According to the developed technology drinking water is passed consistently in the downward direction through the mechanical and chlorineanionite exchanger filters. In the latter, the main part of HCO3̄ and SO42--water ions are exchanged for Cl-anions of anionite. Then the water is collected in the tank, from where it is pumped to the hot water heater through the ultraviolet disinfection unit. After the depletion of the anionite by HCO3̄ and SO42--anions, it is regenerated by a solution of 8–12 % NaCl. The results of research by the anion exchangers Purolite A200EMBCl and AB-17-8 are plotted. It is noted that when the specific consumption of salt for regeneration is of about 45–55 kg/m³, working exchange capacity of the A200EMBCl occurs to be in the range 300–370 g-Eqv/m³. For anionization of water, the residual concentration of HCO3̄-ions are changed from 0.5 to 3.2 mg-Eqv/l. The average concentration of these anions occurs to be between 1.8 and 2.2 mg-Eqv/l, when their initial value is 4.4 mg-Eqv/l.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>Cl-анионирование</kwd><kwd>питьевая вода</kwd><kwd>обменная емкость</kwd><kwd>удель- ный расход</kwd><kwd>расход соли</kwd><kwd>регенерация</kwd><kwd>очистка</kwd><kwd>анионит</kwd><kwd>катионы жесткости</kwd><kwd>бикарбонат- ионы</kwd><kwd>качество воды</kwd><kwd>Н-катионирование</kwd><kwd>умягчение</kwd><kwd>концентрация</kwd></kwd-group><kwd-group xml:lang="en"><kwd>Cl-anion exchange process</kwd><kwd>drinking water</kwd><kwd>exchange capacity</kwd><kwd>specific consumption</kwd><kwd>consumption of salt</kwd><kwd>regeneration</kwd><kwd>purification</kwd><kwd>anionite</kwd><kwd>cations of hardness</kwd><kwd>bicarbonate ions</kwd><kwd>water quality</kwd><kwd>H-cation exchange</kwd><kwd>softening</kwd><kwd>concentration</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Нутриенты в питьевой воде [Электронный ресурс]. Режим доступа: https://filtrofinfo.ru/o-vode/nutrienty-v-pit-evoj-vode.html</mixed-citation><mixed-citation xml:lang="en">Nutrients in drinking water. (20.04.2015). Available at: https://filtrofinfo.ru/o-vode/nutrienty-v-pit-evoj-vode.html. (in Russian)</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Консенсус экспертов. Доклад совещания экспертов. Общественное здравоохранение и окружающая среда [Электронный ресурс]. Женева: Всемирная организация здравоохранения, 2008. Режим доступа: http://www.who.int/water_sanitation_health/dwq/chemicals/Ca%2BMg_consensusrep_ru.pdf</mixed-citation><mixed-citation xml:lang="en">The consensus of experts – Report of the Expert Meeting. Public Health and the Environment. (2008). Geneva, World Health Organization. Available at: http://www.who.int/water_sanitation_health/dwq/chemicals/Ca%2BMg_consensusrep_ru.pdf. (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Вред дистиллированной воды [Электронный ресурс]. Режим доступа: http://www.live-wtr.ru/vred-distillirovannoi-vody.</mixed-citation><mixed-citation xml:lang="en">Harm of distilled water. Available at:  http://www.live-wtr.ru/vred-distillirovannoi-vody (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Европейская Директива 80/778/EEC от 15 июля 1980 г. по качеству питьевой воды, предназначенной для употребления человеком // Официальный журнал Европейского Союза. 1980. L229. С. 11–29.</mixed-citation><mixed-citation xml:lang="en">European Directive 80/778/EEC of 15 July 1980 on the Quality of Drinking Water Intended for Human Consumption. (1980). Official Journal of the European Union, L229, 11-29 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Руководство по качеству питьевой воды: в 2 т. 2-е издание. Женева: ВОЗ, 1996. Т. 2. Критерии Безопасности для здоровья и другая сопутствующая информация. С. 237–240.</mixed-citation><mixed-citation xml:lang="en">A Guide to Drinking Water Quality. Vol. 2: Safety Criteria for Health and Other Related Information. 2nd Ed. (1996). Geneva, WHO, 237–240 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Гигиенические требования к качеству воды нецентрализованного водоснабжения. Санитарная охрана источников: СанПиН 2.1.4.1175–02 : введ. 01.03.2003. М., 2003. 20 с.</mixed-citation><mixed-citation xml:lang="en">Sanitary Regulations and Norms (SanPiN) 2.1.4.1175–02. Hygienic Requirements to Water Quality of Centralized Water Supply. Sanitary Protection of Sources. Moscow ,2003. 20 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Питьевая вода. Гигиенические требования к качеству воды централизованных систем водоснабжения. Контроль качества. Санитарно-эпидемиологические правила и нормативы: СанПиН 2.1.4.1074–01. М., 2002. 90 с.</mixed-citation><mixed-citation xml:lang="en">Sanitary Regulations and Norms (SanPiN) 2.1.4.1074–01. Drinking Water. Hygienic Requirements to Water Quality of Centralized Water Supply Systems. Quality Control. Sanitary-Epidemiological Rules and Norms. ?oscow, 2002. 90 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Питьевая вода. Гигиенические требования к качеству воды, расфасованной в емкости. Контроль качества. Санитарно-эпидемиологические правила и нормативы: СанПиН 2.1.4.1116–02. Москва, 2002. 22 с.</mixed-citation><mixed-citation xml:lang="en">Sanitary Regulations and Norms (SanPiN 2.1.4.1116–02). Drinking Water. Hygienic Requirements to the Quality of the Water Packaged in Capacity. Quality Control. Sanitary-Epidemiological Rules and Standards. Moscow, 2002. 22 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Лифщиц, О. В. Справочник по водоподготовке котельных установок. / О. В. Лифщиц. Изд. 2-е, перераб. и доп. М.: Энергия, 1976. 288 с.</mixed-citation><mixed-citation xml:lang="en">Lifshchits O. V. (1976) Handbook for Process Boilers. 2nd Ed. Moscow, Energiya Publ. 288. (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Мещерский, Н. А. Эксплуатация водоподготовительных установок электростанций высокого давления. 2-е изд., перераб. / Н. А. Мещерский. М.: Энергоатомиздат, 1984. 408 с.</mixed-citation><mixed-citation xml:lang="en">Meshcherskii N. A. (1984) Operation of Power Plant Water Treatment Units of High Pressure. 2nd Ed. Moscow, Energoatomizdat Publ. 408  (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Методические указания. Нормы качества сетевой и подпиточной воды водогрейных котлов, организация водно-химического режима и химического контроля: РД 24.031.120–91. Москва, 1991. 31 с.</mixed-citation><mixed-citation xml:lang="en">Guidance Document (RD) 24.031.120–91. Methodic Instructions. Norms of Quality of the Network and Feed Water of Water Boilers, Organization of Water-Chemical Regime and Chemical Control.  Moscow, 1991. 31 (in Russian).</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
