<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">energy</journal-id><journal-title-group><journal-title xml:lang="ru">Энергетика. Известия высших учебных заведений и энергетических объединений СНГ</journal-title><trans-title-group xml:lang="en"><trans-title>ENERGETIKA. Proceedings of CIS higher education institutions and power engineering associations</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1029-7448</issn><issn pub-type="epub">2414-0341</issn><publisher><publisher-name>BNTU</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.21122/1029-7448-2017-60-2-118-132</article-id><article-id custom-type="elpub" pub-id-type="custom">energy-1058</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ЭЛЕКТРОЭНЕРГЕТИКА</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>ELECTRICAL POWER ENGINEERING</subject></subj-group></article-categories><title-group><article-title>МЕТОДЫ ИЗМЕРЕНИЯ ВЛИЯНИЙ МОЛНИИ ПУТЕМ ИМИТАЦИИ ЕЕ УДАРОВ С ИНТЕРВАЛЬНОЙ ОЦЕНКОЙ РЕЗУЛЬТАТОВ ИЗМЕРЕНИЙ</article-title><trans-title-group xml:lang="en"><trans-title>METHODS OF MEASURING THE EFFECTS OF LIGHTNING BY SIMULATING ITS STRIKES WITH THE INTERVAL ASSESSMENT OF THE RESULTS OF MEASUREMENTS</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Криксин</surname><given-names>П. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Kriksin</surname><given-names>P. V.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Адрес для переписки: Криксин Павел Васильевич  – ООО «АЭСАТ Электрик», ул. Логойская, 19, комн. 9, 220053, Минский р-н, д. Валерьяново, Республика Беларусь. Тел.: +375 29 606-22-21    kriksinpavel@gmail.com</p></bio><bio xml:lang="en"><p>Address for correspondence: Kriksin Pavel V. – The “AESAT Electric” Limited Liability Company, 19 room 9, Logoiskaya str., 220053, Minsk rayon, the village of Valeryanovo, Republic of Belarus Tel.: +375 29 606-22-21    kriksinpavel@gmail.com</p></bio><email xlink:type="simple">kriksinpavel@gmail.com</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>«АЭСАТ Электрик» ООО</institution><country>Беларусь</country></aff><aff xml:lang="en"><institution>“AESAT Electric” Limited Liability Company</institution><country>Belarus</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2017</year></pub-date><pub-date pub-type="epub"><day>07</day><month>03</month><year>2017</year></pub-date><volume>60</volume><issue>2</issue><fpage>118</fpage><lpage>132</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Криксин П.В., 2017</copyright-statement><copyright-year>2017</copyright-year><copyright-holder xml:lang="ru">Криксин П.В.</copyright-holder><copyright-holder xml:lang="en">Kriksin P.V.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://energy.bntu.by/jour/article/view/1058">https://energy.bntu.by/jour/article/view/1058</self-uri><abstract><p>Представлены результаты разработки новых методов более точной интервальной оценки экспериментальных значений напряжений, возникающих при ударах молнии в молниеотводы, на заземляющих устройствах подстанций и в цепях контрольных кабелей, позволяющие повысить достоверность полученных данных молниевых помех на 28 %. Более точные значения интервальной оценки достигнуты за счет разработки модели измерений, учитывающей наряду с измеряемыми величинами различные погрешности измерений, и специальной обработки результатов измерений. В результате этого интервал нахождения истинного значения искомого напряжения определен с точностью 95 %. Методы могут быть использованы для измерительных комплексов ИК-1 и ИКП-1, состоящих из генератора апериодических импульсов, генератора высокочастотных импульсов и селективных вольтметров соответственно. Для оценки эффективности указанных методов выполнены серии экспериментальных оценок напряжения на заземляющих устройствах десяти действующих высоковольтных подстанций по разработанным и традиционным методам. Результаты оценок подтвердили возможность определения истинных значений напряжений в широком диапазоне, что необходимо учитывать в процессе технической диагностики молниезащиты подстанций при анализе результатов измерений и разработке мероприятий по снижению влияний молнии. Также сравнительный анализ результатов измерений по разработанным и традиционным методам показал, что истинное значение искомого напряжения может превышать измеренное на величину до 28 %, что необходимо учитывать при дальнейшем анализе параметров молниезащиты на объекте и разработке корректирующих мероприятий. Методы апробированы при обследовании электромагнитной обстановки на 27 действующих высоковольтных электрических подстанциях с открытым распределительным устройством 110 кВ. Применение методик позволило повысить точность собираемой информации, правильность оценки электромагнитной обстановки высоковольтных подстанций с ОРУ 110 кВ, эффективность адекватных разрабатываемых мероприятий по защите от влияний молнии. </p></abstract><trans-abstract xml:lang="en"><p>The article presents the results of the development of new methods aimed at more accurate interval estimate of the experimental values of voltages on grounding devices of substations and circuits in the control cables, that occur when lightning strikes to lightning rods; the abovementioned estimate made it possible to increase the accuracy of the results of the study of lightning noise by 28 %. A more accurate value of interval estimation were achieved by developing a measurement model that takes into account, along with the measured values, different measurement errors and includes the special processing of the measurement results. As a result, the interval of finding the true value of the sought voltage is determined with an accuracy of 95 %. The methods can be applied to the IK-1 and IKP-1 measurement complexes, consisting in the aperiodic pulse generator, the generator of high-frequency pulses and selective voltmeters, respectively. To evaluate the effectiveness of the developed methods series of experimental voltage assessments of grounding devices of ten active high-voltage substation have been fulfilled in accordance with the developed methods and traditional techniques. The evaluation results confirmed the possibility of finding the true values of voltage over a wide range, that ought to be considered in the process of technical diagnostics of lightning protection of substations when the analysis of the measurement results and the development of measures to reduce the effects of lightning are being fulfilled. Also, a comparative analysis of the results of measurements made in accordance with the developed methods and traditional techniques has demonstrated that the true value of the sought voltage may exceed the measured value at an average of 28 %, that ought to be considered in the further analysis of the parameters of lightning protection at the facility and in the development of corrective actions. The developed methods have been tested in surveys of the electromagnettic environment of 27 active high voltage electric substations with a 110 kV outdoor switchgear. The application of the techniques amended the accuracy of the information collected, the correctness of the evaluation of the electromagnetic environment of high-voltage substations with a 110 kV outdoor switchgear, the effectiveness of the developed adequate measures to protect against lightning effects.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>имитационное моделирование</kwd><kwd>интервальная оценка</kwd><kwd>молния</kwd><kwd>молниезащита</kwd><kwd>подстанция</kwd></kwd-group><kwd-group xml:lang="en"><kwd>simulation</kwd><kwd>interval estimation</kwd><kwd>lightning</kwd><kwd>lightning protection</kwd><kwd>substation</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Базелян, Э. М. Физика молнии и молниезащиты / Э. М. Базелян, Ю. П. Райзен. М.: Физматлит, 2001. 320 с.</mixed-citation><mixed-citation xml:lang="en">Bazyelyan E. M., Raizen Yu. P. (2001) Physics of Lightning and Lightning Protection. Moscow, Fizmatlit Publ. 320 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Rakov, V. A. Lightning. Physics and Effects / V. A. Rakov, M. A. Uman. Cambridge: Cambridge University Press, 2003. 687 p.</mixed-citation><mixed-citation xml:lang="en">Rakov V. A., Uman M. A. (2003) Lightning. Physics and Effects. Cambridge, Cambridge University Press. 687. DOI: 10.1017/CBO9781107340886.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Петров, С. Р. Компьютерные программы для анализа и проектирования устройств заземления и молниезащиты / С. Р. Петров, Р. К. Борисов // Первая Российская конференция по заземляющим устройствам: сб. докл. Новосибирск: Сибирская энергетическая академия, 2002. – С. 41–43.</mixed-citation><mixed-citation xml:lang="en">Petrov S. R., Borisov R. K. (2002) Computer Programs for Analysis and Design of Grounding and Lightning Protection. Pervaia Rossiiskaia Konferentsiia po Zazemliaiushchim Ustroistvam: Sb. Dokl. [First Russian Conference on Grounding Devices. Collected Presentations]. Novosibirsk, Siberian Energy Academy, 41–43 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Методические указания по обеспечению электромагнитной совместимости на объектах электросетевого хозяйства: Стандарт организации СТО 56947007-29.240.044–2010. Введ. 21.04.2010. М.: ОАО «Федеральная сетевая компания единой энергетической системы», 2010. 147 с.</mixed-citation><mixed-citation xml:lang="en">Open Joint Stock Company “Federal Grid Company of Unified Energy System”. Standard of the Organization 56947007-29.240.044–2010 (2010). Methodic Instructions for Ensuring Electromagnetic Compatibility at Electric Grid Facilities. Moscow. 147 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Методические указания по определению электромагнитных обстановки и совместимости на электрических станциях и подстанциях: Стандарт организации СО 34.35.311–2004 / Российское открытое акционерное общество энергетики и электрификации «ЕЭС России». М.: Изд-во МЭИ, 2004. 78 с.</mixed-citation><mixed-citation xml:lang="en">Standard of Organizatiuon “Russian Joint Stock Company of Power and Electrification of Russia” 34.35.311–2004 (2004) Methodical Instructions for Dtermining of the Electromagnetic Environment and Compatibility in Power Stations and Substation. Moscow, Publishing House of the Moscow Power Engineering Institute. 78 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Кострикин, А. М. Проблемы электромагнитной совместимости на объектах электроэнергетики и пути их решения / А. М. Кострикин, П. В. Криксин // Энергия и Менеджмент. 2010. № 3. С. 44–45.</mixed-citation><mixed-citation xml:lang="en">Kostrikin A. M., Kriksin P. V. (2010) Problems of Electromagnetic Compatibility at Electric Power Facilities and Ways to Solve them. Energiya i Menedzhment [Power and Management], (3), 44–45 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Криксин, П. В. Моделирование и анализ процессов, происходящих при стекании тока молнии в грунт / П. В. Криксин, М. И. Фурсанов // Энергия и Менеджмент. 2012. № 2. С. 14–19.</mixed-citation><mixed-citation xml:lang="en">Kriksin P. V., Fursanov M. I. (2012) Modeling and Analysis of the Processes Occurring in the Drainage of the Lightning Current into the Ground. Energiya i Menedzhment [Power and Management], (2), 14–19 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Криксин, П. В. Обследование электромагнитной обстановки на электрических подстанциях. Теория и практика / П. В. Криксин // Энергия и Менеджмент. 2011. № 3. С. 25–35.</mixed-citation><mixed-citation xml:lang="en">Kriksin P. V. (2011). The Survey of Electromagnetic Environment at Electric Substations. Theory and Practice. Energiya i Menedzhment [Power and Management], (3), 25–35 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Криксин, П. В. Вторичные влияния молнии. Как она поражает электронику предприятий / П. В. Криксин, М. И. Фурсанов // Энергия и Менджмент. 2014. № 1. С. 34–40.</mixed-citation><mixed-citation xml:lang="en">Kriksin P. V., Fursanov M. I. (2014) Secondary Effects of Lightning. How it Affects Electronic Devices of Eneterprises. Energiya i Menedzhment [Power and Management], (1), 34–40 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Фурсанов, М. И. Криксин П. В. Моделирование и анализ токов в заземляющих устройствах электроустановок / М. И. Фурсанов, П. В. Криксин // Энергия и Менеджмент. 2010. № 3. С. 16–21.</mixed-citation><mixed-citation xml:lang="en">Fursanov M. I., Kriksin P. V. (2010) Modeling and Analysis of Currents in the Grounding Devices of Electric Installations. Energiya i Menedzhment [Power and Management], (3), 16–21 (in Russian).</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
